The 12.1-Inch Multi-Parameter Patient Monitor is an advanced clinical monitoring solution designed for hospitals, emergency care, operating rooms, and intensive care environments. It provides continuous monitoring of essential vital signs with a large, clear display and expandable options for advanced patient assessment.
Alla Meditechs professionella kunder inom hälso- och sjukvård kan skicka serviceärenden via Kundserviceportal.
För att få ytterligare 2 månaders förlängd garanti, vänligen registrera era produkter här.För alla supportresurser och kontaktinformation, besök vårt Supportcenter.
Kommer snart.
Upptäck de avancerade funktioner som skiljer våra produkter från mängden
Detaljerade tekniska specifikationer och prestandaparametrar
| Parameter | Specification |
|---|---|
| Lead Mode | 5 Leads (R, L, F, N, C / RA, LA, LL, RL, V) |
| Lead Selection | I, II, III, aVR, aVL, aVF, V |
| Waveform Display | 2 Channels |
| Derivative Mode | 3 Derivatives (R, L, F / RA, LA, LL) |
| Line Selection | I, II, III |
| Gain | ×2.5, ×5, ×10, ×20 mm/mV |
| Heart Rate Range | Adult: 30–300 bpm / Neo-Ped: 30–350 bpm |
| HR Accuracy | ±1% or ±1 bpm |
| Resolution | 1 bpm |
| Sensitivity | >200 μV p-p |
| Differential Input Impedance | >5 MΩ |
| CMRR | Monitoring >105 dB / Operation >105 dB / Diagnostic >85 dB |
| Electrode Offset Potential | ±300 mV |
| Leakage Current | <10 μA |
| Baseline Recovery | <10 s after defibrillation |
| ECG Signal Range | ±8 mV (Vp-p) |
| Bandwidth | Surgery: 1–15 Hz / Monitoring: 0.5–35 Hz / Diagnostic: 0.05–100 Hz |
| Calibration Signal | 1 mV (Vp-p), ±5% accuracy |
| ST Monitoring Range | -2.0 to +2.0 mV |
| Arrhythmia Detection | ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT >2, PVC, TACHY, BRADY, MISSED BEATS, PNP, PNC |
| T-Wave Suppression | 1.2 mV |
| HR Averaging | Average of last 6 R-R intervals |
| Display Update Rate | 1 s |
| Alarm Function | Available |
| Verification Function | Available |
| Condition | Response |
|---|---|
| Bigeminy Ventricular | 80 bpm |
| Bigeminy Ventricular Alternate Slow | 57 or 63 bpm |
| Bigeminy Ventricular Alternate Fast | 122 or 123 bpm |
| Systole Bidirectional | 95 bpm |
| HR Change Response (80→120 bpm) | Average 3.7 s (Range 3.2–4.1 s) |
| HR Change Response (80→40 bpm) | Average 4.7 s |
| Parameter | Specification |
|---|---|
| Measurement Method | Oscillometric |
| Modes | Manual / Auto / STAT |
| Auto Measurement Interval | 1, 2, 3, 4, 5, 10, 15, 30, 60, 90, 120, 240, 480, 960 min |
| STAT Mode Duration | 5 min |
| Pulse Rate Range | 40–240 bpm |
| Alarm Type | SYS, DIA, MEAN |
| Patient Mode | SYS | DIA | MEAN |
|---|---|---|---|
| Adult | 40–270 mmHg | 10–215 mmHg | 20–235 mmHg |
| Pediatric | 40–200 mmHg | 10–150 mmHg | 20–165 mmHg |
| Neonatal | 40–135 mmHg | 10–100 mmHg | 20–110 mmHg |
| Parameter | Specification |
|---|---|
| Resolution | 1 mmHg |
| Accuracy | Maximum mean error ±5 mmHg / Maximum standard deviation ±8 mmHg |
| Overpressure Protection | Adult: 297±3 mmHg / Pediatric: 240±3 mmHg / Neonatal: 147±3 mmHg |
| Parameter | Specification |
|---|---|
| Channels | 2 Channels |
| Measuring & Alarm Range | 0–50°C |
| Resolution | 0.1°C |
| Accuracy | ±0.1°C |
| Update Interval | Approx. 1 s |
| Average Time Constant | <10 s |
| Parameter | Specification |
|---|---|
| Channels | 2 Channels |
| Supported Parameters | ART, PA, CVP, RAP, LAP, ICP, P1, P2 |
| Parameter | Range |
|---|---|
| ART | 0–300 mmHg |
| PA | -6–120 mmHg |
| CVP / RAP / LAP / ICP | -10–40 mmHg |
| P1 / P2 | -10–300 mmHg |
| Parameter | Specification |
|---|---|
| Sensor Sensitivity | 5 μV/V/mmHg |
| Impedance | 300–3000 Ω |
| Resolution | 1 mmHg |
| Accuracy | ±2% or ±1 mmHg |
| Update Interval | Approx. 1 s |
| Parameter | Specification |
|---|---|
| Display Type | 12.1" Color TFT Display (Sharp Japan) |
| Waveforms Display | Up to 7 Waveforms |
| Alarm Indicator | 1 LED (Yellow/Red) |
| Power Indicator | Green LED |
| Battery Charge Indicator | Yellow LED |
| Sound Modes | 3 Alarm Sound Modes |
| Parameter | Specification |
|---|---|
| ECG Output | BNC |
| Output Amplitude | 1 V/mV |
| Accuracy | <5% |
| Impedance | 50 Ω |
| Signal Delay | <20 ms |